HP INTEGRITY RX3600 User Manual

Page 267

Advertising
background image

10. Power up to EFI. See

“Powering On and Powering Off the Server” (page 93)

for this

procedure.
a.

Verification from EFI
1.

Respond YES to prompts regarding copying information onto the new board.

2.

Verify the serial number and model string data information copied onto the new
I/O board.
a.

Boot to EFI.

b.

Enter service mode using the following command:

Shell> sysmode service
Current System Mode: ADMIN
You are now in SERVICE mode.

c.

Use the sysset command to verify that all values are set:

Shell> sysset

System Information:
Manufacturer: hp
Product Name: server rx3600
Product Number: AB463A
Secondary Product Number is Identical
Serial number: SGH43442VB
Secondary Serial Number is Identical
UUID: 3C33C58E-2E5A-11D8-A33B-4188C0AEFAE2 (Valid)
Secondary UUID is Identical
Product ID: 0x301

b.

Enable the TPM.
1.

Access the EFI Shell.

2.

Enter info sec to display the server security settings on the screen. The TPM is
disabled by default.

3.

Enter secconfig to display a list of configurable security settings.

4.

Enter secconfig tpm on to enable the TPM.

c.

Verify the system board replacement and operation using either the iLO 2 MP or EFI
commands.

11. Viewing Warnings

To view warning access the EFI shell and run the info warning command.

12. Verifying I/O cards

To verify the I/O cards access the EFI shell and run the info io command.

Shell> info io

I/O INFORMATION

BOOTABLE DEVICES

Order Media Type Path
----- ---------- ---------------------------------------
1 CDROM Acpi(HWP0002,PNP0A03,0)/Pci(2|1)/Usb(0, 0)/CDROM(Entry0)/HD(Part1,Sig00000000)
2 HARDDRIVE
Acpi(HWP0002,PNP0A03,400)/Pci(2|0)/Sas(Addr5000C5000034749D,Lun0)/HD(Part1,Sig4EE76936-BE45-47FA-9AC7-B0ECF2D912F2)

3 HARDDRIVE
Acpi(HWP0002,PNP0A03,400)/Pci(2|0)/Sas(Addr5000C50000347735,Lun0)/HD(Part1,Sig92C8CB4C-E0F2-11DA-8002-D6217B60E588)

4 HARDDRIVE
Acpi(HWP0002,PNP0A03,400)/Pci(2|0)/Sas(Addr5000C50000347735,Lun0)/HD(Part3,Sig92C8CB7E-E0F2-11DA-8004-D6217B60E588)

Seg Bus Dev Fnc Vendor Device Slot
# # # # ID ID # Path
--- --- --- --- ------ ------ --- -----------
00 00 01 00 0x103C 0x1303 XX Acpi(HWP0002,PNP0A03,0)/Pci(1|0)
00 00 01 01 0x103C 0x1302 XX Acpi(HWP0002,PNP0A03,0)/Pci(1|1)
00 00 01 02 0x103C 0x1048 XX Acpi(HWP0002,PNP0A03,0)/Pci(1|2)

I/O Backplane Upgrade

267

Advertising