Phy properties screen – HP INTEGRITY RX3600 User Manual

Page 298

Advertising
background image

PHY Properties Screen

The PHY Properties screen enables you to view and modify PHY specific settings. To access PHY
Properties, press Enter on the PHY Properties field from the Advanced Adaptor Properties
screen.
You can perform the following actions from PHY Properties:.
•

To display the next PHY, press N.

•

To display the previous PHY, press P.

•

To reset the Link Error Counts for this PHY or all PHYs, press Enter on Reset Link Error
Counts. Resetting Link Error Counts issues a PHY Link Error Reset. The following prompt
displays when you press Enter:

Are you sure you want to reset Phy error counts?
Reset error counts for this Phy only
Reset error counts for all Phys
Cancel

NOTE:

The Link Error Settings values on this screen display the current values for this PHY

only, and are not modifiable. To modify the Threshold values, you must return to Advanced
Adapter Properties

screen.

PHY

Displays the PHY number current information.

SAS Port

Indicates the associated SAS Port (0 to N) as configured on this
adapter.

Link Status

Indicates the PHY link status. Possible values are:
•

Enabled, Unknown Link Rate

•

PHY Disabled

•

Enabled, negotiation failed

•

Enabled, SATA OOB Complete

•

Enabled, 1.5 Gbs

•

Enabled, 3.0 Gbs

Discovery Status

32 bit hexidecimal value indicating the discovery status for the PHY
or Expander. Currently defined values are:
•

Discovery completed successfully - 0x00000000

•

Loop Detected - 0x00000001

•

Unaddressable device exists - 0x00000002

•

Multiple Ports - 0x00000004

•

Expander Error - 0x00000008

•

SMP Timeout - 0x00000010

•

Out of route entries - 0x00000020

•

SMP Response Index Does Not Exist - 0x00000040

•

SMP Response Function Failed - 0x00000080

•

SMP CRC error - 0x00000100

Device Identifier

Indicates the ASCII device identifier string extracted from the
device's Inquiry Data.

Scan Order

Indicates the scan order for this device (equivalent of a SCSI ID for
parallel SCSI).

Device Information

Indicates if a device is SAS.

SAS Address

Indicates the SAS Address of this device.

Link Error Setting

Invalid DWORDs - Number of invalid dwords that have been
received outside of PHY reset sequences, since the last PHY
Link Error Reset.

a

•

•

Loss of DWORD Sync - Number of times, since the last PHY
Link Error Reset, that dword synchronization was lost and the
link reset sequence occurred.

a

298

Core I/O Card Utilities