Table 24. main setup screen – Intel SR9000MK4U User Manual

Page 169

Advertising
background image

Intel

®

Server System SR9000MK4U Product Guide

147

When the power button is pressed and released while the main power is on, the power
turns off or the operating system begins a shut down process. If the power button is held
down, a forced power off is executed. If the power is forced off, then the server is not
powered on after AC power recovery even if on is selected as the Power On option. Use
the power button to power on the system, and then press and release the power button to
shut down the server without forcing it into the power off state.

Discard changes and

Exit

Does not store the changed values in CMOS, and exits setup. Clicking

on the menu item causes the system to prompt the user for a Yes or No

response.

Yes: Saves the changes and exits the utility.

No: Aborts the action.

Restore Defaults

Restores the setting values to default. Clicking on the menu item

causes the system to prompt the user for a Yes or No response.

Yes: Loads the system setup defaults.

No: Aborts the action.

Exit

Exits setup. If there are any changes, the user is prompted for a Yes or

No response.

Yes: Saves the changes and reboots the system.

No: Aborts the action.

Table 24. Main Setup Screen

Primary Menu Item

Sub Menu Item

Option

Description

Power On Option

After Power Failure

[Return]

On

Off

Determines whether the system

should boot once power returns

after a power loss.

Return: Return to previous state

at power loss occurs. If power

loss occurs at system on state,

the system returns to the

power-on state at power

recovery. If it occurs at system

off state, the system will be

remaining off state.

On: Power on after power

recovery.

Off: Not goes to power on state

(Power off) after power

recovery.