Server System SR9000MK4U Product Guide

Internal Chassis Features

Power Supply Subsystem

The 12 V hot-swap power supply modules are rated at 1390 W over an input range of 200
- 240 VAC, and at 990 W over an input range of 100-127 VAC.

The power supply module has two outputs, that is, +12 V and +5 Vsb. The standby
voltages +5 Vsb is active anytime AC input power is applied to the power supply.

The power supply module is connected to the main board directly and can be used in 1+1
redundant mode.

Note: Two power supplies must be installed and plugged in when a 110 V outlet is used. Hot-

swapping and redundancy are not available under this condition.

One power supply can be used when it is connected to a 220 VAC outlet. Under this
condition, redundancy is available and a power supply can be hot-swapped if necessary.

Note: This value is applied to one power supply.

Table 6. 1390 W Power Supply Configuration

AC Input

Current

See Note

Redundancy

Hot-swap

Remarks

200-240 V

9.5 A

Supported

Supported

Restriction of loading is

needed. Two power

supplies must be

installed to enable

redundancy and hot-

swap.

100-127 V

12 A

Not supported

Not supported

Restriction of loading is

needed. Two power

supplies must be

installed top operate the

server system.