External device setup manual – IDEC High Performance Series User Manual

Page 115

Advertising
background image

97

2 Mitsubishi

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

Con

nection

to a PLC

External Device Setup Manual

2.4.6

MELSEC-FX Series

2.4.7

MELSEC-Q/QnA: in case using Ethernet Unit setting

1. MICRO/I settings - Project Settings dialog box

This Host I/F driver does not support MELSECNET/H and MELSECNET/10 network.

Item

Setting

Interface

RS232C, RS422

Data Bits

Use the same settings as
for the MICRO/I.

7 (fixed)

Baud Rate

9600 bps (fixed)

Parity

Even (fixed)

Stop Bits

1 (fixed)

- When using CPU Direct for the connection, the PLC program scan time will increase when it starts communicating with

the MICRO/I. Investigate this under your actual operating conditions.

- To connect MELSEC-FX series PLC and MICRO/I, check the following two things.

Unchecked the communication setting by the programming software.
Data Register 8120 (D8120) must be 0.

- If the PLC is MELSEC-FX3U or MELSEC-3UC, check the following two thins too.

If MICRO/I connects to CH1 on the PLC, Data Register 8400 (D8400) must be 0.
If MICRO/I connects to CH2 on the PLC, Data Register 8420 (D8420) must be 0.

Item

Setting

Communication Interface tab

IP Address

Set the IP address of MICRO/I.

Subnet mask

Set the subnet mask of MICRO/I.

Default Gateway

Set the default gateway of MICRO/I.

Host I/F Network tab

IP Address

Set the IP address of PLC.

Port Number

Set the port number of PLC to communicate with MICRO/I.