301

8 Hitachi

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

Con

nection

to a PLC

External Device Setup Manual

Word Device

Device Name

Device Symbol

Address Range

Read
/Write

Address
Gradual

MICRO/I

PLC

Input Relay

XW

X

0 - 7F0

R/W

Output Relay

YW

Y

0 - 7F0

R/W

Internal Relay

RW

R

0 - 7F0

R/W

Global Link

GW

G

0 - FF0

R/W

System Register

SW

S

0 - BF0

R

E Word

EW

EW

400 - FF0

R/W

Event

WE

E

0 - F0

R/W

Keep Relay

KW

K

0 - 1F0

R/W

On-Delay Timer (contact)

TW

T

0 - 1F0

R

One Shot Timer (contact)

UW

U

0 - 70

R

Up/Down Counter (contact)

CW

C

0 - 30

R

On-Delay Timer (elapsed value)

TC

T

0 - 1FF

R

On-Delay Timer (setup value)

TS

T

0 - 1FF

R/W

One Shot Timer (elapsed value)

UC

U

0 - 7F

R

One Shot Timer (setup value)

US

U

0 - 7F

R/W

Up/Down Counter (elapsed value)

CC

C

0 - 3F

R

Up/Down Counter (setup value)

CS

C

0 - 3F

R/W

Work Register

FW

FW

0 - BFF

R/W

Data Register

*1

*1. When you use word device as bit device, the bit position reverses the order, as shown in the example.
Example: specified address read address

DW 0-0 DW 0-15
DW 0-1 DW 0-14
: :
DW 0-14 DW 0-1
DW 0-15 DW 0-0

DW

DW

0 - FFF