External Device Setup Manual

18.4.4

MICREX-SX series (connecting to the CPU unit loader connection connector or using the In-
terface Module.)

18.4.5

MICREX-SX series (connecting to the Ethernet port or using the Ethernet module.)

1. MICRO/I settings

2. PLC Settings

Items

Details

Interface

RS232C, RS485

Baud Rate (bps)

Use the same

settings as for the MICRO/I.

38400

Data Bits

8

Stop Bits

1

Parity

Even

Flow Control

None

- The communication settings are fixed.

- When you connect to the Interface Module,set the RS232C or RS485 operation mode as loader setting.

Set up the mode switch of Interface Module as below.

RS232C: Mode switch is No.1.or No.3
RS485:Mode switch is No.2.or No.3.

Item

Setting

IP Address (MICRO/I)

Set the IP address of MICRO/I in Communication Interface tab.

Subnet Mask

Set the subnet mask of MICRO/I in Communication Interface tab.

Default Gateway

Set the default gateway of MICRO/I in Communication Interface tab.

IP Address (PLC)

Set the IP address of PLC in Host I/F Network tab.

Port Number (PLC)

Set the port number of PLC in Host I/F Network tab.
The default is 507.

Item

Setting

IP Address

Set the IP address of PLC.

Subnet mask

Set the subnet mask of PLC .

Default Gateway

Set the default gateway of PLC.