Chapter 2

286

External Device Setup Manual

Word Device

WindO/I-NV2 Device
Name

R/W

WindO/I-NV2 address

PLC Device Name

PLC address

Timer (Current Value)

R

TC0 - TC777

Timer

(Current Value)

0000 - 0777

Ext.Counter(Current Value)

R

ETC1000 - ETC1777

1000 - 1777

Counter (Current Value)

R

CC0 - CC777

Counter

(Current Value)

0000 - 0777

Ext.Counter (Current Value)

R

ECC1000 - ECC1777

1000 - 1777

Register (A)

R/W

RA0 - RA1576

Register

a0000 - a1576

Ext.Register (A)

R/W

ERA2000 - ERA7576

a2000 - a7576

Register (B)

R/W

RB0 - RB1776

b0000 - b1776

Ext.Register (B)

R/W

ERB2000 - ERB3776

b2000 - b3776

Register (09)

R/W

R09_ 0 - R09_ 776

09000 - 09776

Register (19)

R/W

R19_ 0 - R19_ 776

19000 - 19776

Register (29)

R/W

R29_ 0 - R29_ 776

29000 - 29776

Register (39)

R/W

R39_ 0 - R39_ 776

39000 - 39776

Register (49)

R/W

R49_ 0 - R49_ 776

49000 - 49776

Register (59)

R/W

R59_ 0 - R59_ 776

59000 - 59776

Register (69)

R/W

R69_ 0 - R69_ 776

69000 - 69776

Register (79)

R/W

R79_ 0 - R79_ 776

79000 - 79776

Register (89)

R/W

R89_ 0 - R89_ 776

89000 - 89776

Register (99)

R/W

R99_ 0 - R99_ 776

99000 - 99776

Register (E)

R/W

RE0 - RE1776

E0000 - E1776

Ext.Register (E)

R/W

ERE2000 - ERE7776

E2000 - E7776

System Memory

R

S0 - S2176

System Memory

#0000 - #2176

File Register (1)

R/W

F1_ 0 - F1_ 37776

File Register1

000000 - 037776

File Register (2)

R/W

F2_ 0 - F2_ 177776

File Register2

000000 - 177776

File Register (3)

R/W

F3_ 0 - F3_ 177776

File Register3

000000 - 177776

- Set all devices using octal.

- Confirm the PLC manuals as device or device address may not use according to PLC.

- R/W specifies Read and Write device. R specify Read only device.

- Word device address below “Register (A)” increase +2. (The other device increase +1.)

- Device address of WindO/I NV2 does not display as the number of figure used PLC.

Example: if you set to “Register 19005” using WindO/I NV2, it set to not “R19_ 005” but “R19_5”.