22.4 Environment Settings

The communication port settings for FloBoss series and MICRO/I host port are as follows.

22.4.1

Connecting with FloBoss COM1 (RS485) or COM2 (RS232C)

Items

Details

Interface

RS232C, RS485

Baud Rate [bps]

Use the same settings as for the
MICRO/I.

1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200

Data Bits

7, 8

Stop Bits

1, 2

Parity

None, Even or Odd

Flow Control

None

HMI Group No.

Set the Group No. of MICRO/I.

HMI Unit No.

Set the Unit No. of MICRO/I.

Controller Group No.

Set the Group No. of FloBoss in Host I/F Network tab.

Controller Unit No.

Set the Unit No. of FloBoss in Host I/F Network tab.