Allowed communication settings for MicroLogix, SLC 500, PLC-5, ControlLogix and CompactLogix are as follows.

4.4.1

MicroLogix, SLC 500 (Full Duplex)

Item

Setting

Baud Rate (bps)

*1

*2

*1. Select using RSLogix software (set Chan0 to System of Controller-Channel Configuration).
*2. The setting for this item must match the setting on the MICRO/I Series unit.

1200, 2400, 4800, 9600 or 19200

Data Bits

*2

8 (fixed)

Parity

*1

*2

None or Even

Stop Bits

*1

*2

1

Flow Control

Hardware or None

Serial Interface

RS232C

Driver

*1

DF1

Full-Duplex

*3

*3. Be certain to select as indicated.

Control Line

*1

No

Handshaking

*3

Error Detection

*1

CRC

*3

Embedded Response

*1

Auto Detect

Duplicate Packet Detect

*1

Enable

Node Address

*1

*2

*4

*4. Be certain to select as indicated.Select the MICRO/I Node Address using the Node Address (MICRO/I) under

Project Settings

in WindO/

I-NV2 software.

0 to 254 (decimal)

Advertising
This manual is related to the following products: