If the temperature of all thermal planes is between the low and high thresholds for a fan speed, the
fan continues to operate at that fan speed.

If the temperature of any thermal plane exceeds the high threshold specified for a fan speed, the
fan speed increases to the next higher speed. If the temperature of any thermal plane exceeds the
high threshold for the high speed and remains above the threshold for five minutes, the system
automatically shuts down to prevent damage.

If the temperature of any thermal plane falls below the low threshold for a fan speed, the fan
decreases its speed to the next lower speed. If the temperature of any thermal plane falls below the
high threshold for the low speed, the fan operates at the low speed.

If the temperature of any thermal plane exceeds the high temperature threshold for any of the fan
speeds, the software sends a message to the system log.

The table below outlines the default low and high temperature thresholds for each fan speed, as well as
the operating level and noise level of the fans at each fan speed.

Default low and high temperature thresholds for thermal planes and fan speeds

TABLE 22

Fan Speed Description Low Temperature

Threshold

High Temperature
Threshold

Fan Operating
Level (% of
Capacity)

Fan Noise
Level

4

High

50 ° C

80 ° C

100

78 dB

3

Medium

49 ° C

59 ° C

50

66 dB

2

Medium-low 48 ° C

58 ° C

37

63 dB

1

Low

N/A

57 ° C

25

56 dB

Command syntax

If desired, you can change the default low and high temperature thresholds for a particular thermal
plane and fan speed. For example, to change the low and high thresholds of the medium fan speed for
the management module or modules to 56 ° C and 72 ° C, respectively, enter the following command at
the global CONFIG level of the CLI.

device(config)# fan-threshold mp speed-3 56 72

Syntax: fan-threshold module [ speed-1 high-threshold ] [ speed-2 low-threshold high-threshold ] [
speed-3 low-threshold high-threshold ] [ speed-4 low-threshold high-threshold ]

For the module parameter, specify one of the following:

lp - Changes low and high temperature thresholds for the Interface modules.

mp - Changes low and high temperature thresholds for the management module.

sfp - (FSX 800 and FSX 1600 only) Changes low and high temperature thresholds for the switch
fabric modules.

The fan speeds are as follows:

speed-1 - low

speed-2 - medium-low

speed-3 - medium

speed-4 - high (shutdown temperature)