Managing the chassis and modules, Overview, Displaying chassis status and temperature readings – Brocade FastIron SX Series Chassis Hardware Installation Guide User Manual

Page 95

Advertising
background image

Managing the Chassis and Modules

Overview......................................................................................................................... 93

Displaying chassis status and temperature readings......................................................93

Managing the cooling system..........................................................................................97

Displaying the Syslog configuration and static and dynamic buffers............................ 103

Syslog messages for PCI (hardware) errors................................................................. 105

Managing the switch fabric modules (FSX 800 and FSX 1600 only)............................ 105

Displaying management module CPU usage............................................................... 106

Removing MAC address entries................................................................................... 106

Overview

This chapter contains information about refining the configuration of, monitoring, and managing the
hardware components.

Displaying chassis status and temperature readings

You can display the following information about your Brocade device:

Status of the power supplies

Status of the fans

Temperature readings and thresholds of the management and interface modules

Temperature readings and thresholds of the switch fabric modules (FSX 800 and FSX 1600 only)

The MAC address of the chassis

The following shows an example of the show chassis command output on the FSX 800.

device# show chassis

Chassis Type: FastIron SX 800

Power supply 1 not present

Power supply 2 not present

Power supply 3 (H1250C - AC - Regular) present, status ok

Power supply 4 not present

Fan 1 ok, speed (auto): 1<->[[2]]<->3<->4

Fan 2 ok, speed (auto): 1<->[[2]]<->3<->4

Fan 3 ok, speed (auto): 1<->[[2]]<->3<->4

Fan 4 ok, speed (auto): 1<->[[2]]<->3<->4

Fan 5 ok, speed (auto): 1<->[[2]]<->3<->4

Fan 6 ok, speed (auto): 1<->[[2]]<->3<->4

Fan controlled temperature:

Rule 1/3 (MGMT CARDS THERMAL PLANE): 41.5 deg-C

Rule 2/3 (LINE CARDS THERMAL PLANE): 44.0 deg-C

Rule 3/3 (SWITCH FABRIC CARDS THERMAL PLANE): 49.5 deg-C

Fan speed switching temperature thresholds:

Rule 1/3 (MGMT CARDS THERMAL PLANE):

Speed 1: NM<----->57 deg-C

Speed 2: 48<----->58 deg-C

Speed 3: 49<----->59 deg-C