10/100 and gigabit port pinouts, Cable specifications – Brocade FastIron SX Series Chassis Hardware Installation Guide User Manual
Page 162
10/100 and gigabit port pinouts
FIGURE 58 Pin assignment and signalling for 10/100Base-TX and 1000Base-T ports
Cable specifications
The table below lists the specifications for the cables used with the 10/100, Gigabit, and 10-Gigabit
Ethernet ports.
NOTE
Cable installation and network configuration will affect overall transmission capability. The numbers
provided below represent the accepted recommendations of the various standards. For network-
specific recommendations, consult your local Brocade reseller or system engineer.
Cable length summary table
TABLE 34
Cable
Type
Connector
Type
Core
Diameter(microns)
Modal
Bandwidth(MHz*km)
or Wavelength (nm)
Range
(meters)
1000Base-BX-D Single-
mode Fiber
(SMF)
LC connector for
SFP module
9
1490 nm
2 - 10000
(10km)
1000Base-BX-U SMF
LC connector for
SFP module
9
1310 nm
2 - 10000
(10km)
1000Base-LHA
SMF
LC connector for
SFP module
9
1550 nm
2 - 70000
(70km)
1000Base-LHB
SMF
LC connector for
SFP module
9
1550 nm
2 - 120000
(120km)
10/100 and gigabit port pinouts
160
Brocade FastIron SX Series Chassis Hardware Installation Guide
53-1003092-01