Cooling, Fsx 800 – Brocade FastIron SX Series Chassis Hardware Installation Guide User Manual

Page 154

Advertising
background image

Environmental conditions for the chassis (Continued)

TABLE 27

Description

Range

Operating temperature 0 ° - 40 ° C (32 ° - 104 ° F)

Operating altitude

10,000 feet maximum with the following power supplies:

32014-xxx

32016-xxx

6,600 feet maximum with the following power supplies:

32004-xxx

32005-xxx

32007-xxx

32008-xxx

32010-xxx

NOTE
The above are manufacturing part numbers, which are inscribed on the power supply (top)
labels.

Relative humidity

5 to 95%, non-condensing

Operating noise

Based on ISO 7779

Based on fan and power supply operating noise.

Storage Environment

Storage temperature

-25 ° to 70 ° C (-10 ° to 158 ° F)

Storage humidity

95% maximum relative humidity, non-condensing

Storage altitude

0 - 4572 meters (0 - 15,000 feet) maximum

Cooling

The cooling system is contained within the system’s fan tray assembly and modules.

FSX 800

The fan tray in the FSX 800 is located on the right side of the chassis. This position assumes you are
facing the front of the chassis, not the rear.

The fans cool the CPU, main memory, and voltage regulators. The fans move the air from the left side
of the device to the right side of the device as shown in the figure below.

Cooling

152

Brocade FastIron SX Series Chassis Hardware Installation Guide

53-1003092-01