Cooling, Fsx 800 – Brocade FastIron SX Series Chassis Hardware Installation Guide User Manual
Page 154
Environmental conditions for the chassis (Continued)
TABLE 27
Description
Range
Operating temperature 0 ° - 40 ° C (32 ° - 104 ° F)
Operating altitude
10,000 feet maximum with the following power supplies:
•
32014-xxx
•
32016-xxx
6,600 feet maximum with the following power supplies:
•
32004-xxx
•
32005-xxx
•
32007-xxx
•
32008-xxx
•
32010-xxx
NOTE
The above are manufacturing part numbers, which are inscribed on the power supply (top)
labels.
Relative humidity
5 to 95%, non-condensing
Operating noise
Based on ISO 7779
Based on fan and power supply operating noise.
Storage Environment
Storage temperature
-25 ° to 70 ° C (-10 ° to 158 ° F)
Storage humidity
95% maximum relative humidity, non-condensing
Storage altitude
0 - 4572 meters (0 - 15,000 feet) maximum
Cooling
The cooling system is contained within the system’s fan tray assembly and modules.
FSX 800
The fan tray in the FSX 800 is located on the right side of the chassis. This position assumes you are
facing the front of the chassis, not the rear.
The fans cool the CPU, main memory, and voltage regulators. The fans move the air from the left side
of the device to the right side of the device as shown in the figure below.
Cooling
152
Brocade FastIron SX Series Chassis Hardware Installation Guide
53-1003092-01