Mean time between failure – Brocade FastIron SX Series Chassis Hardware Installation Guide User Manual

Page 159

Advertising
background image

Chassis power surge and drop protection

TABLE 31

Property

Protection Mechanism

Power surge

MOV and Spark Gap protection

Power drop

An AC loss of >15ms will cause the power supply to shut down due to input under-voltage

Mean time between failure

The table below lists the Mean Time Between Failure (MTBF) for the FastIron X Series chassis devices
and modules. The MTBF is the average estimated time, in units of hours, before a hardware failure may
occur.

MTBF for the FastIron X Series chassis and modules

TABLE 32

Configuration or Module

Temperature MTBF (hours)

FSX

FSX chassis + fan module + backplane

40 ° C

1,003,172

FSX chassis + fan module + backplane + one AC power supply

40 ° C

269,386

FSX chassis + fan module + backplane + one DC power supply

40 ° C

272,432

AC power supply (non-POE supply)

40 ° C

368,282

AC POE power supply

40 ° C

139,000

DC power supply

40 ° C

374,000

FSX Management Modules

IPv6 Management Module with 256 MB SDRAM and no optics

40 ° C

292,557

IPv6 Management Module with 256 MB SDRAM and 12 optics

40 ° C

211,053

IPv6 Management Module with 512 MB SDRAM and no optics

40 ° C

287,425

IPv6 Management Module with 512 MB SDRAM and 12 optics

40 ° C

208,369

IPv4 Management Module with no optics

40 ° C

287,664

IPv4 Management Module with 12 optics

40 ° C

152,154

SX-FI-2XGMR-XL and the SX-FI-2XGMR-XL-PREM6 management modules

40 ° C

506,155

FSX 800

FSX 800 + fan module + two switch fabric modules

40 ° C

230,584

Mean time between failure

Brocade FastIron SX Series Chassis Hardware Installation Guide

157

53-1003092-01

Advertising