Brocade FastIron SX Series Chassis Hardware Installation Guide User Manual

Page 79

Advertising
background image

S3: Reserved

S4: SX-FI-8XG 8-port 10G Fiber OK 8 0024.3821.7548

S5: SX-FI-48GPP 48-port Gig Copper + PoE+ OK 48 0024.3821.7500

S6:

S7:

S8:

S9: SX-FIZMRXL6 0-port Management Active 0

{ Status : OK }

S10: Standby 0

Syntax:show module

The Status column shows the module status. The status can be one of the following:

OK - The module is up and running

ACTIVE - This applies to the FSX 800 and FSX 1600 management and switch fabric modules
only. This indicates that the module is the active module as opposed to the standby module.

UNACTIVE -- This status indicates a lost connection, failed initialization, or failed power. Take
the module out and reinsert to continue.

STANDBY - This applies to the FSX 800 and FSX 1600 management and switch fabric
modules only. This indicates that the module is the standby module as opposed to the active
module.

FAILED - The management module was unable to bring up an interface module properly. If
you observe this status, make certain that the interface module is installed properly. For more
information, refer to

Installing management and interface modules

on page 60.

DISABLED - The module is not up and running.

Installing FastIron SX Devices

Brocade FastIron SX Series Chassis Hardware Installation Guide

77

53-1003092-01

Advertising