DANGER

The devices are very heavy, especially when fully populated with modules and power supplies.
TWO OR MORE PEOPLE ARE REQUIRED WHEN LIFTING, HANDLING, OR MOUNTING THESE
DEVICES.

DANGER

Make sure the rack or cabinet housing the device is adequately secured to prevent it from
becoming unstable or falling over.

DANGER

Mount the devices you install in a rack or cabinet as low as possible. Place the heaviest device
at the bottom and progressively place lighter devices above.

For each FastIron X Series that you install in a rack, you must provide four mounting screws with which
to secure the chassis.

To mount the chassis in a rack using the built-in mounting brackets, perform the following tasks.

1.

Determine the position of each chassis in the rack.

2.

Position two of the four mounting screws for each chassis that you plan to mount in the rack
according to the spacings of the keyhole slots on the brackets. Do not secure the screws
completely; leave approximately 1/4 inch of clearance between the back of the screw head and the
rack.

1

Keyhole slots

FIGURE 21 Positioning two or four mounting screws in a rack.