2 special application dc power output connections, 3 relays - programmable – Fire-Lite MS-10UD Series FACP User Manual

Page 33

Advertising
background image

MS-5UD & MS-10UD Series Manual — P/N 52626:C4 3/7/2014

33

Output Circuits

Installation

2.4.2 Special Application DC Power Output Connections

Special Application Resettable and Nonresettable 24 VDC power is available on the MS-5UD and
MS-10UD control panel.

2.4.3 Relays - Programmable

The MS-5UD and MS-10UD control panels provide a factory default programmed alarm relay, fail-
safe trouble relay and supervisory relay. Each relay can be programmed to activate for other con-
ditions (refer to “Relays” on page 69). Each Form-C relay is rated for 2 amps @ 30VDC (resistive)
and 0.5 amps @ 30 VAC (resistive).

Note that relay connections must be power-limited.

Figure 2.8 Special Application Auxiliary Power

Special Application
4-Wire Smoke Detector Power (500 mA)
24 VDC filtered, resettable power for 4-wire smoke detectors can be
obtained from these terminals (power-limited)

Special Application
Resettable or Nonresettable Power (500 mA)
24 VDC filtered, resettable or nonresettable power can be obtained
from these terminals (power-limited)
• Jumper JP31 pins 1 & 2 for nonresettable power (as illustrated in
figure to right)
• Jumper JP31 pins 2 & 3 for resettable power

-

+

-

+

ms-

1

0

UDt

b9

.w

mf

4

3

2

1

Figure 2.9 Relay Terminals

Note: Relay contacts are shown with
power applied to the panel and no active
troubles, alarms or supervisories.
The Trouble Relay is a fail-safe relay
which will transfer on any trouble or total
power failure.

m

s

10

ud

re

la

y

.w

m

f

Advertising
This manual is related to the following products: