Section 3: Programming

3.1 User Programming

The MS-5UD/MS-10UD FACP is completely field programmable using the panel keypad and
requires no special software skills.

Site-specific programming may be accomplished in the following ways:

Manual programming or editing, using the FACP keypad

Remote Programming and Editing Feature - allows creation and editing of site-specific custom
programs using a Windows-based computer and modem. For programs requiring a large
amount of data entry, this method may be preferred. A PK-CD programming CD ROM can be
ordered for this purpose

Local Programming and Editing Feature - allows creation and editing of site-specific custom
programs using a Windows-based computer and USB connection. For programs requiring a
large amount of data entry, this method may be preferred. A PK-CD programming CD ROM
can be ordered for this purpose

The System All Normal screen will be displayed in a programmed system with no active alarms,
troubles or supervisories, as illustrated below:

NOTICE TO USERS, INSTALLERS, AUTHORITIES HAVING JURISDICTION, AND OTHER INVOLVED PARTIES

This product incorporates field-programmable software. In order for the product to comply with the requirements in the Standard

for Control Units and Accessories for Fire Alarm Systems, UL 864, certain programming features or options must be limited to

specific values or not used at all as indicated below:

Program feature or

option

Permitted in UL

864? (Y/N)

Possible settings

Settings permitted in

UL 864

Trouble Call Limit

N

Refer to “Trouble Call Limit (Dialer Runaway Prevention)” on

page 89.

Trouble Call Limit = 0 (factory default): unlimited calling to

Central Station for any trouble condition

Trouble Call Limit = 1 - 99: limits call for each unique trouble

to from 1 to 99 within a 24 hour period

Trouble Call Limit = 0

for unlimited Central

Station trouble calls

Remote Download

Y

Refer to“Remote Download” on page 113.

Remote Download - Proprietary No

Remote Download - Proprietary Yes

Remote Download
Proprietary Yes for

Proprietary system

intended to protect only

contiguous properties

Combo

Y

Refer to Table 3.1 on page 62.

One Waterflow and one

Supervisory device

Combo

w/AutoResettable

Superv

Y

Refer to Table 3.1 on page 62.

One Waterflow and one

Supervisory device

!

CAUTION:

FIRE PROTECTION ENABLED

WHILE PROGRAMMING THE FACP, THE FIRE PROTECTION CAPABILITIES OF THE CONTROL
PANEL ARE ENABLED. PROGRAMMING MODE TIMES-OUT AFTER 10 MINUTES OF
INACTIVITY.

SYSTEM ALL NORMAL