User's Guide ______________________________________________________________________

Configuration

NOTE

You have chosen the initial settings for WMT700 when placing the
order. In case you want to check and/or change the settings, see the
instructions in this section.

Otherwise, you can start using WMT700 directly after the installation.

The initial settings have been configured at the factory according
to the customer specifications you have given when ordering the
product. For available options, see section Ordering Options on
page 23.

Configuration Overview

You can configure WMT700 settings for serial communication or
analog output with configuration commands using the serial port.
However, you must set the port to the configuration mode before
starting configuration. It is also possible to use one serial port in
the configuration mode while operating WMT700 from the other
serial port.

WMT700 provides commands for:

- Parameter handling

- Wind measurement control

- Diagnostics

- Information

If the messages parameter is set to 1 (response for parameter
setting is enabled, see Appendix D, Configuration Parameters, on
page 205),
WMT700 responds to an invalid command with an
error message. If the messages parameter is set to 0 (response for
parameter setting is disabled), WMT700 does not send any error
messages. You can fetch the most recent error data in the
configuration mode with the ERRORS command, see section
ERRORS — Get Error Codes and Counts on page 116.

NOTE

You can configure WMT700 by sending individual commands or by
loading a configuration file to the sensor. For instructions on configuring
all settings at once using configuration files, see section User-
Configurable Data Messages on page 119.

110 __________________________________________________________________ M211095EN-E