Heating power, Table 27, Heating power supply requirements – Vaisala WMT700 User Manual

Page 89: Table 28, Heating power and extension cable

Advertising
background image

Chapter 4 ________________________________________________________________ Installation

Heating Power

Table 27 below lists the minimum power supply requirements of
each WMT700 heating option.

NOTE

In maritime environments, the normal input voltage ranges are: operating
voltage 10 … 30 VDC (-10% … +30%) and heating voltage
24 … 30 VDC (-10% … +30%), as defined in the maritime standard
IEC 60945.

Table 27

Heating Power Supply Requirements

Heating Option

Heating Voltage

Required Heating
Power Supply

None

-

-

Transducers

24 … 36 VDC

40 W

Transducers and arms

24 … 36 VDC

200 W

Transducers, arms and body

24 VDC

350 W (2 m cable)

Power and Cable Recommendations for Fully
Heated WMT700

Table 28 below shows cable and power recommendations. If a
longer than a 10 meter cable is needed, it is recommended to use
Junction Box with Cable (WMT70CABLE12) for extending the
cable length.

NOTE

The minimum operation voltage for a fully heated WMT700
(transducers, arms, and body heated) is 16 V, if a separate power supply
unit is used for operation.


Table 28

Heating Power and Extension Cable

Wire Type/
Cable Length

2 m

WMT70CABLE1

*

10 m

WMT70CABLE2*

20 m

30 m

40 m

0.5 mm2/AWG20 24V 400 W

28 V 400 W

-

-

-

1 mm2/AWG17

-

-

28V 400 W

30 V 400 W

32 V 400 W **

1.5 mm2/AWG15 -

-

-

-

30 V 400 W

* Vaisala standard connection cable.
** Not for maritime use.