Meas — start measurement, Open — enter configuration mode, Table 41 – Vaisala WMT700 User Manual

Page 138: Measurement mode commands

Advertising
background image

User's Guide ______________________________________________________________________

Table 41

Measurement Mode Commands

Command

Description

$aMEAS

Starts wind measurement in single measurement mode. The
duration of the measurement is based on the user-
configurable averaging time.

$aOPEN

Switches the serial port to configuration mode.

$aPOLL,y

Fetches latest measurement data from WMT700.

$aSLEEP

Switches WMT700 from normal operating mode to low-power
mode.

where

$

=

Fixed text

a

=

WMT700 address. If the value is 0, it refers to any
WMT700 address

y

=

Identification number for the data message format. For a
list of the data message formats, see Table 40 on page 128

MEAS — Start Measurement

This command starts wind measurement in single measurement
mode based on the user-configurable averaging time. WMT700
does not send the data message automatically. Use the polling
command to fetch the measurement data in the required format.

$aMEAS<CR><LF>

where

$

=

Fixed text

a

=

WMT700 address. If the value is 0, it refers to any
WMT700 address

OPEN — Enter Configuration Mode

This command switches the serial port to the configuration mode.

$aOPEN<CR><LF>

where

$

=

Fixed text

a

=

WMT700 address. If the value is 0, it refers to any
WMT700 address

NOTE

WMT700 automatically returns to normal operating mode, if no
commands are received in two minutes, or multiple unrecognized
commands are detected.

136 __________________________________________________________________ M211095EN-E

Advertising