Table 36

Wind Measurement Items for Data Messages

Item

Description

\ad

Address

\dm

Wind direction minimum calculated over the averaging period

\dx

Wind direction maximum calculated over the averaging period

\gu

Wind gust speed

\lu

Wind lull speed

\rg

Signal quality

\st

Speed of sound

\Ts

Sonic temperature

\va

Validity of the measurement data. The available values are:
1 = Valid wind measurement data
0 = Unable to measure

\w1

Wind direction when the peak speed (\wp) occurred

\wd

Wind direction, average

\wm

Wind speed minimum calculated over the averaging period

\wp

Wind speed maximum calculated over the averaging period

\ws

Wind speed, average

\wx

Wind speed average, x component

\wy

Wind speed average, y component

Table 37

Control Character and Checksum Items for
Data Messages

Item

Description

\01

SOH (start of heading)

\02

STX (start of text)

\03

ETX (end of text)

\04

EOT (end of transmission)

\cr

CR (carriage return)

\lf

LF (line feed)

\se

Checksum calculation end point

\sp

Print checksum

\ss

Checksum calculation start point