Missing readings – Vaisala WMT700 User Manual

Page 164

Advertising
background image

User's Guide ______________________________________________________________________

Example of the command and response:

W5

W5P1200013.2TDE

Interpretation of the example message:

-

02H (<STX>, start of transmission)

- Sensor ID: W

- Averaging in seconds: 5

- Sensor status: P = pass

- Wind direction: 120

- Wind speed: 0013

- . (dot character)

- Wind speed unit: T = meters per second

- Checksum (most significant digit): D

- Checksum (least significant digit): E

-

03H (<ETX>, end of transmission)

Missing Readings

If data is missing due to a measurement problem, the WS425 A/B
ASCII message reports 999.9 for wind speed.

162 __________________________________________________________________ M211095EN-E