Com2_interf i – Vaisala WMT700 User Manual

Page 208

Advertising
background image

User's Guide ______________________________________________________________________

Parameter
Name

Default
Value

Allowed Values

Units

Description

com1_baud
com2_baud

4

0 = 300
1 = 1200
2 = 2400
3 = 4800
4 = 9600
5 = 19200
6 = 38400
7 = 57600
8 = 115200

Baud rates for serial ports COM1 and
COM2. Changes take effect only after
reset or the RESET command.
Note that a low bit rate can affect
measurement timing, if WMT700 cannot
send the data message before a new
measurement starts.

com1_data
com2_data

8

7 = 7 data bits
8 = 8 data bits

Data bits for serial ports COM1 and
COM2. Changes take effect only after
reset or the RESET command.

com1_delay
com2_delay

20

0 … 10000

ms

COM1 and COM2 Response delay in
milliseconds.

com2_interf

0

0 = RS-485
1 = RS-422
2 = SDI-12
3 = RS-232

Interface for serial port COM2. (The
interface for serial port COM1 cannot be
changed.)

com1_parity
com2_parity

0

0 = None
1 = Even
2 = Odd

Parity for serial ports COM1 and COM2.
Changes take effect only after reset or
the RESET command.

com1_protocol

0

0 … 11

Protocol for serial port COM1.
0 = WMT700
2 = WS425 F/G ASOS
3 = WS425 A/B ASCII
4 = WS425 A/B NMEA Standard
5 = WS425 A/B NMEA Extended
6 = WS425 A/B WAT11
8 = MES12
11 = WMT700 NMEA MWV

com2_protocol 0

0 … 11

Protocol for serial port COM2.
0 = WMT700
1 = SDI-12
2 = WS425 F/G ASOS
3 = WS425 A/B ASCII
4 = WS425 A/B NMEA Standard
5 = WS425 A/B NMEA Extended
6 = WS425 A/B WAT11
8 = MES12
11 = WMT700 NMEA MWV

com1_stop
com2_stop

1

1 = 1 bit
2 = 2 bits

Stop bits for serial ports COM1 and
COM2.
Changes take effect only after reset or
the RESET command.

freqType

0

0 = Push-pull
1 = Active pull-down
2 = Active pull-up

AOUT1 frequency output type. Setting 1
requires external pull-up resistor.
Setting 2 requires external pull-down
resistor.

heaterOn

1

0 = Heater off
1 = Automatic

Heater control. When the value is set to
1, WMT700 controls the heaters based
on the temperature and other conditions.

messages

1

0 = Disabled
1 = Enabled

Response for parameter setting.

206 __________________________________________________________________ M211095EN-E