Chapter 5 _________________________________________________________________ Operation
To start continuous measurement, use the START command.
You can stop the measurement with the STOP command. For
instructions, refer to START — Start Continuous Measurement
and STOP — Stop Wind Measurement on page 115.
WS425 A/B NMEA Extended
Commands
This command polls data from WMT700.
$WIP<id>Q,*<chk><CR><LF>
where
$WIP
= Fixed text
<id>
= Data ID; A … Z
Q
= Fixed text
*
= Fixed text
<chk>
= Checksum (8-bit XOR, excluding $ and *)
<CR>
= Carriage return code, ASCII 0DH
<LF>
= Line feed code, ASCII 0AH
Table 48
Checksum Table
ID Character <id>
Checksum <chk>
Polling String
A
72
$WIPAQ,*72<CR><LF>
B
71
$WIPBQ,*71<CR><LF>
C
70
$WIPCQ,*70<CR><LF>
D
77
$WIPDQ,*77<CR><LF>
E
76
$WIPEQ,*76<CR><LF>
F
75
$WIPFQ,*75<CR><LF>
G
74
$WIPGQ,*74<CR><LF>
H
7B
$WIPHQ,*7B<CR><LF>
I
7A
$WIPIQ,*7A<CR><LF>
J
79
$WIPJQ,*79<CR><LF>
K
78
$WIPKQ,*78<CR><LF>
L
7F
$WIPLQ,*7F<CR><LF>
M
7E
$WIPMQ,*7E<CR><LF>
N
7D
$WIPNQ,*7D<CR><LF>
O
7C
$WIPOQ,*7C<CR><LF>
NOTE
To use WMT700 with the NMEA Extended profile, either set the
autoSend parameter to 0 to enable polling or define a fixed output
interval with the autoInt parameter. If you are using automatic messages,
the value for the autoSend parameter must be set to 15.