Chapter 5 _________________________________________________________________ Operation

To start continuous measurement, use the START command.
You can stop the measurement with the STOP command. For
instructions, refer to START — Start Continuous Measurement
and STOP — Stop Wind Measurement on page 115.

WS425 A/B NMEA Extended
Commands

This command polls data from WMT700.

$WIP<id>Q,*<chk><CR><LF>

where

$WIP

= Fixed text

<id>

= Data ID; A … Z

Q

= Fixed text

*

= Fixed text

<chk>

= Checksum (8-bit XOR, excluding $ and *)

<CR>

= Carriage return code, ASCII 0DH

<LF>

= Line feed code, ASCII 0AH

Table 48

Checksum Table

ID Character <id>

Checksum <chk>

Polling String

A

72

$WIPAQ,*72<CR><LF>

B

71

$WIPBQ,*71<CR><LF>

C

70

$WIPCQ,*70<CR><LF>

D

77

$WIPDQ,*77<CR><LF>

E

76

$WIPEQ,*76<CR><LF>

F

75

$WIPFQ,*75<CR><LF>

G

74

$WIPGQ,*74<CR><LF>

H

7B

$WIPHQ,*7B<CR><LF>

I

7A

$WIPIQ,*7A<CR><LF>

J

79

$WIPJQ,*79<CR><LF>

K

78

$WIPKQ,*78<CR><LF>

L

7F

$WIPLQ,*7F<CR><LF>

M

7E

$WIPMQ,*7E<CR><LF>

N

7D

$WIPNQ,*7D<CR><LF>

O

7C

$WIPOQ,*7C<CR><LF>

NOTE

To use WMT700 with the NMEA Extended profile, either set the
autoSend parameter to 0 to enable polling or define a fixed output
interval with the autoInt parameter. If you are using automatic messages,
the value for the autoSend parameter must be set to 15.