Table 61, General – Vaisala WMT700 User Manual

Page 193

Advertising
background image

Chapter 8 _____________________________________________________________ Technical Data

Table 61

General

Property

Description/Value

Heating

No heating: 0 W
Average heating power 30 W
Peak transducer heating power: 40 W
Average transducer and array arm heating:
150 W
Average transducer, arm, and body heating:
250 W
Peak transducer, arm, and body heating: 350 W
at 24 VDC

Operating temperature

-10 ... +60 °C
-40 ... +60 °C
-55 ... +70 °C

Operating voltage:

9 ... 36 VDC; see details in Table 26 on page 84

Absolute maximum

40 VDC

Heating voltage:

Typical ranges

24 ... 36 VDC

Absolute maximum

40 VDC

IP class

IP66/IP67

Material:
Body
Transducers
Mounting kit


Stainless steel AISI316
Silicone
Stainless steel AISI316

Dimensions:
Height
Width
Depth


348 mm
250 mm
285 mm

Weight

WMT700 Wind Sensor: 1.8 kg
Mounting adapter: 0.3 kg
Fix70 Mounting Kit 1.4 kg

Connector

Hummel 7.106 series

NOTE

In maritime environments, the normal input voltage ranges are:
operating voltage 10 … 30 VDC (-10% … +30%) and heating voltage
24 … 30 VDC (-10% … +30%), as defined in the maritime standard
IEC 60945.

NOTE

Any temporary element or object (such as snow, ice, or a bird) blocking
the measurement path between the ultrasonic transducer heads may affect
the wind measurement accuracy or even invalidate the output data.