SDI-12 Data Messages

When the SDI-12 profile is selected, the data message sent by
WMT700 depends on the command that you use before fetching
the data with the aD0! command.

WS425 A/B SDI-12 Message for C and M
Command

When you have given the commands aC! or aM! followed by
aD0!, the response is the following:

a<WS><WD><x><y><s><CR><LF>

where

a

=

Single-digit WMT700 address that corresponds to
the first character of the address value

<WS>

=

Polar wind speed in selected units
Format: +(ss)s.s

<WD>

=

Polar wind direction in degrees
Format: +(dd)d.d

<x>

=

x component of wind speed in selected units
Format: ±(ss)s.s

<y>

=

y component of wind speed in selected units
Format: ±(ss)s.s

<s>

=

Static speed of sound in miles per hour
Format: ±(ss)s.s

<CR><LF>

=

Terminates the response

The above are measurement data fields.

Missing Readings

If data is missing due to a measurement problem (for example,
blocked paths between transducers), the measurement data is
replaced with 999.9.

Example of the command and response when data is missing:

7D0!

7+999.9+999.9+999.9+999.9+999.9 <CR><LF>