Mounting Procedure

To upgrade from WS425 to WMT700:

1.

Uninstall WS425.

2.

If you are using a WMT700 cable, run the cable through the
WS425 mounting kit. Connect the cable to the WMT700
wind sensor.

If you are using a WS425 cable, ensure the pre-installed O-
ring seal sits properly in the plastic male connector
(between the existing WS425 cable and the adapter cable).
Connect the WS425 cable to the WS425 adapter cable (see
Figure 47 below). Run the adapter cable through the WS425
mounting kit. Connect the cable to the WMT700 wind
sensor.

1103-012

Figure 47

WS425 Adapter Cable

3.

Tighten the connector by rotating the connector by hand
clockwise; see Figure 31 on page 72.

Ensure that the connector is properly tightened before
proceeding to the next step. If you are unable to tighten the
connector, loosen the mounting adapter fixing screws,
remove the mounting adapter, and connect the cable. After
that, reattach the mounting adapter.

4.

Attach the WMT700 sensor body to the WS425 mounting
kit and tighten the bolt.

5.

Remove the transportation damper protecting the array and
store it for future use.

6.

Connect the cable to the data acquisition system and power
supply. Connect the wires according to section Wiring on
page 99.

WMT700 is now ready for operation.