Digital communication profile, Digital communication units, Table 9 – Vaisala WMT700 User Manual

Page 27: Table 10, Digital communication options

Advertising
background image

Chapter 2 ___________________________________________________________ Product Overview

Digital Communication Profile

Ordering option 5, Digital Communication Profile, defines the
communication protocol used for the sensor. WS425 options are
usable and backwards compatible when replacing WS425 sensor
with a WMT700 unit. MARINE and WIND TURBINE options
are customer-specific profiles.

Table 9

Digital Communication Profile

Option Communication Profile
0

WMT70 - default mode

9600, 8, N, 1 Polled

1

WS425 - ASCII

2400, 8, N, 1

Polled

2

WS425 - NMEA Extended (v 0183)

9600, 8, N, 1

Auto send 1/s

3

WS425 - SDI-12 (v 1.3)

1200, 7, E, 1

Polled

4

WS425 - ASOS

2400, 8, N, 1

Polled

5

ROSA - MES12

9600, 8, N, 1

Polled

6

US AWOS - NMEA Standard

2400, 8, N, 1

Autosend 5/s

7

FAA - Federal

9600, 8, N, 1

Polled

8

AWS520 - NMEA Extended (v 0183) 4800, 8, N, 1

Auto send 1/s

A

MARINE1 (v 0183)

4800, 8, N, 1

Auto send 1/s

B

MARINE2 (v 0183)

9600, 8, N, 1

Auto send 1/s

C

WIND TURBINE1 (default)

9600, 8, N, 1

Polled

D

WIND TURBINE2 (v 0183)

9600, 8, N, 1

Auto send 1/s

Digital Communication Units

Ordering option 6, Unit Definition for Digital Communication,
offers four different digital communication options.

Table 10

Digital Communication Options

Option Unit Used
A

Meters per second

B

Knots

C

Miles per hour

D

Kilometers per hour

VAISALA ________________________________________________________________________ 25