Digital communication profile, Digital communication units, Table 9 – Vaisala WMT700 User Manual
Page 27: Table 10, Digital communication options
Chapter 2 ___________________________________________________________ Product Overview
Digital Communication Profile
Ordering option 5, Digital Communication Profile, defines the
communication protocol used for the sensor. WS425 options are
usable and backwards compatible when replacing WS425 sensor
with a WMT700 unit. MARINE and WIND TURBINE options
are customer-specific profiles.
Table 9
Digital Communication Profile
Option Communication Profile
0
WMT70 - default mode
9600, 8, N, 1 Polled
1
WS425 - ASCII
2400, 8, N, 1
Polled
2
WS425 - NMEA Extended (v 0183)
9600, 8, N, 1
Auto send 1/s
3
WS425 - SDI-12 (v 1.3)
1200, 7, E, 1
Polled
4
WS425 - ASOS
2400, 8, N, 1
Polled
5
ROSA - MES12
9600, 8, N, 1
Polled
6
US AWOS - NMEA Standard
2400, 8, N, 1
Autosend 5/s
7
FAA - Federal
9600, 8, N, 1
Polled
8
AWS520 - NMEA Extended (v 0183) 4800, 8, N, 1
Auto send 1/s
A
MARINE1 (v 0183)
4800, 8, N, 1
Auto send 1/s
B
MARINE2 (v 0183)
9600, 8, N, 1
Auto send 1/s
C
WIND TURBINE1 (default)
9600, 8, N, 1
Polled
D
WIND TURBINE2 (v 0183)
9600, 8, N, 1
Auto send 1/s
Digital Communication Units
Ordering option 6, Unit Definition for Digital Communication,
offers four different digital communication options.
Table 10
Digital Communication Options
Option Unit Used
A
Meters per second
B
Knots
C
Miles per hour
D
Kilometers per hour
VAISALA ________________________________________________________________________ 25