Figure 20, Recommended mast length on top of building, Warning – Vaisala WMT700 User Manual

Page 62

Advertising
background image

User's Guide ______________________________________________________________________

1005-001

Figure 20

Recommended Mast Length on Top of Building

where

h = Recommended minimum height for the vertical mast
H = Height of the building
W = Diagonal of the building

WARNING

To protect personnel (and the wind sensor), install a lightning rod with
the tip at least one meter above WMT700. The rod must be properly
grounded, compliant with all local applicable safety regulations. Do not
install the wind sensor above the top of the lightning protection rod.

WARNING

Do not install WMT700 when there is a risk of thunderstorm or lightning
activity in the area.

60 ___________________________________________________________________ M211095EN-E