Table 60

Outputs

Property

Description/Value

Digital outputs:

Communication interfaces

COM1: RS-485
COM2: RS-485, RS-422, RS-232, SDI-12

Communication protocols

WMT700, WS425 ASCII, NMEA Standard
and Extended (version 0183), SDI-12 (version
1.3), WS425 ASOS, ROSA - MES12,
Customized

Bit rate

300, 1200, 2400, 4800, 9600, 19200, 38400,
57600, or 115200

Available averages

Max. 3600 s

Analog outputs:

Wind speed:
Frequency push-pull


Pulse 0 V/10 V: 0 ... 2 kHz (f = 10 Hz/m/s)
(Load > 10 kohm)

Frequency pull-down

Pulse 0.5 V/V

in

-2 V (11 V min.): 0 ... 750 Hz

(Load 50 kohm ±20%)

Frequency pull-up

Pulse 1.5 V/V

in

-4 V (8 V min.): 0 ... 750 Hz

(Load 50 kohm ±20%)

Voltage

0 ... 10 V (U = 100 mV /m/s)

Current

0 ... 20 mA (I = 0.2 mA/m/s)

Wind direction:
Voltage
Current
Potentiometer

0 ... 10 V (U = 20 mV/°)
0 ... 20 mA (I = 50 uA//°)
Reference voltage 1 ... 10 VDC
0 ... V

ref

represents 0 ... 359°

Readout update interval

Max. 4 Hz

Units available

m/s, knots, mph, km/h, V, mA, Hz

Operating mode

Automatic Message or Poll Mode

Virtual temperature

Celsius degrees

NOTE

In extreme weather conditions, ice or snow accumulation may cause a
temporary wind measurement blackout even when the heating is enabled.
WMT700 indicates this with missing readings or in the data message.