Parameter handling commands, Table 35, List of configuration mode commands – Vaisala WMT700 User Manual

Page 113: Cmd x,y<enter

Advertising
background image

Chapter 5 _________________________________________________________________ Operation

Table 35

List of Configuration Mode Commands

Command

Description

?

Displays a list of configuration commands.

BAUD

Changes or displays serial port settings.

CLEARERR Resets error counters.
CLOSE

Switches the serial port to measurement mode.

ERRORS

Fetches the error codes and counter information from WMT700.

G

Displays either all or specified parameters.

H

Displays a list of data messages and available values for
measurement unit, profile, baud rate, interface, and analog
output mode.

MEAS

Starts wind measurement based on the user-configurable
averaging time. WMT700 does not send data messages
automatically.

POLL

Tests data polling.

RESET

Resets WMT700.

S

Changes selected parameters or defines new data messages.

START

Starts continuous measurement.

STOP

Stops continuous measurement.

VERSION

Displays the software version.

WIND_GET Fetches wind calibration information.

Parameter Handling Commands

All the commands in the configurating mode are in the following
form:

>CMD x,y<enter>

| | | | | | |___ Press Enter key to activate the command

| | | | | |_______Value of the parameter
| | | | |_______ Comma
| | | |________ Any parameter in Table 66 on page 205
| | |__________ Space
| |______________ Command
|_________________ Configuration mode prompt

The parameter name and allowed parameter values depend on the
command. For certain commands they are optional. In the
following command descriptions, WMT700 configuration mode
prompt and enter are left out for clarity.

VAISALA _______________________________________________________________________ 111