WS425 A/B NMEA Standard Profile

When the WS425 A/B NMEA Standard profile is configured,
WMT700 sends messages based on the configured automatic
message interval. There are no operating commands available for
the user.

Configurable Parameters

Table 46 below lists the configurable parameters and their
allowed and default values for the WS425 A/B NMEA Standard
profile.

Table 46

Configurable Parameters for WS425 A/B
NMEA Standard Profile

Parameter

Default Value Profile-Specific Allowed

Values

Description

address

1

String with 1 character

Address for WMT700

autoInt

1

0.25 ... 1000
Resolution: 0.25

Automatic message interval in
seconds. Do not select a message
interval that is shorter than the time it
takes to send a data message

autoPort

1

1 = COM1 port
2 = COM2 port

Serial port to which WMT700 sends
automatic data messages

autoSend

0

0 = Automatic messages
disabled
19 = NMEA automatic
data message

Automatic data message number.
Selects the data message format for
automatic messages

com1_protocol

0*

4 = WS425 A/B NMEA
Standard

Profile for serial port COM1

com2_protocol

0

4 = WS425 A/B NMEA
Standard

Profile for serial port COM2

com2_interf

N/A**

0 = RS-485
1 = RS-422
3 = RS-232

Interface for serial port COM2

wndAvg

1

0.25 … 3600
Resolution: 0.25

Averaging time for wind
measurement in seconds

wndOrientation

0

0 = Array facing up
1 = Array facing down

Orientation of the array of WMT700

wndUnit

0**

0 = Meters per second
1 = Miles per hour
2 = Kilometers per hour
3 = Knots

Wind speed unit

wndVector

1

0 = Scalar averaging

Wind averaging method

* The parameter has no protocol-specific default value. It is determined
separately in the configuration code.
** Wind speed unit and COM2 digital communication interface are defined in
the order form. Default setting may be any of the allowed options, and it can be
verified from the unit’s configuration code.