User's Guide ______________________________________________________________________

Configurable Parameters

Table 53 below lists the configurable parameters and their
allowed and default values for the SDI-12 profile.

Table 53

Configurable Parameters for SDI-12 Profile

Parameter

Default
Value

Profile-Specific
Allowed Values

Description

address

1

1, 2, 3, 4, 5, 6, 7, 8, 9

Address for WMT700

autoPort

1

1 = COM1 port
2 = COM2 port

Serial port to which WMT700 sends automatic
data messages

autoSend

0

0 = Automatic messages
disabled

Automatic data message number. Selects the
data message format for automatic messages

com1_protocol

0*

1 = SDI-12

Profile for serial port COM1

com2_baud

1

1 = 1200

Baud rate for serial port COM2.
Changes take effect only after reset or the
RESET command.
Note that low bit rate can affect measurement
timing, if WMT700 cannot send the data message
before new measurement starts

com2_data

7

7 = 7 data bits

Data bits for serial port COM2.
Changes take effect only after reset or the
RESET command

com2_interf

0**

2 = SDI-12

Interface for serial port COM2

com2_parity

1

1 = Even

Parity for serial port COM2.
Changes take effect only after reset or the
RESET command

com2_protocol

1

1 = SDI-12

Profile for serial port COM2

com2_stop

1

1 = 1 bit

Stop bits for serial port COM2.
Changes take effect only after reset or the
RESET command

wndAvg

1

0.25 … 3600
Resolution: 0.25

Averaging time for wind measurement in seconds

wndOrientation 0

0 = Array facing up
1 = Array facing down

Orientation of the array of WMT700

wndUnit

0**

0 = Meters per second
1 = Miles per hour
2 = Kilometers per hour
3 = Knots

Wind speed unit

wndVector

0

0 = Scalar averaging

Wind averaging method

* The parameter has no protocol-specific default value. It is determined
separately in the configuration code.
** Wind speed unit and COM2 digital communication interface are defined in
the order form. Default setting may be any of the allowed options, and it can be
verified from the unit’s configuration code.

To start continuous measurement, use the START command.
You can stop the measurement with the STOP command. For
instructions, refer to sections START — Start Continuous
Measurement
and STOP — Stop Wind Measurement on page
115.