Heating, Digital communication interface, Table 7 – Vaisala WMT700 User Manual

Page 26: Table 8

Advertising
background image

User's Guide ______________________________________________________________________

Heating

Ordering option 3, Heating, defines if the sensor is equipped with
extra heating for demanding environmental conditions. Option 4
providing full sensor heating is best suited for most demanding
environments. Note that power consumption requirement depends
on the selected heating option.

Table 7

Heating

Option

Heating

1

Non-heated

2

Heated transducers (Min. 30 W power supply is needed)

3

Heated transducers and arms (Min. 200 W needed)

4

Heated transducers, arms, and body (Min. 350 W needed)

Digital Communication Interface

Ordering option 4, Digital Communication Interface, defines the
serial line physical interface. Four different standard
communication interfaces are available.

Table 8

Digital Communication Interface

Option

Hardware Interface

A

RS-485 isolated (1 pair)

B

RS-422 isolated

C

RS-232 isolated

D

SDI-12 isolated

24 ___________________________________________________________________ M211095EN-E

Advertising