Non-intensity parameter category timing, Manual timing at a cue level, N o t e – ETC Eos v1.3 User Manual

Page 166

Advertising
background image

152

Eos Operations Manual

Manual Timing at a Cue Level

It is possible to assign a time of “manual”, for manual parameter transition through the associated
fader. Manual times are assigned by using the {Manual} softkey that is displayed when recording a
cue and they can be applied to any parameter.

[Record] <Cue> [4] [Time] {Manual} [Enter] - applies a manual intensity time. If the cue had

previously been given split times, would apply a manual to the upfade. If the cue had a single
time, both the up and down would be “manual” and controlled by the fader.

[Record] <Cue> [4] [Time] [Time] [Manual] [Enter] - applies a manual intensity time to the

downfade. If there was an upfade time for this cue, this command does not change the upfade
time.

[Record] <Cue> [4] {Color} [Time] [Manual] [Enter] - applies a manual time to any color

data changes in cue 4.

Non-intensity Parameter Category Timing

Timing can be also applied for Focus, Color and Beam parameter categories at a cue level. If no
time is applied at a cue level, the defaults established in Setup are used.

When you apply a time to an individual parameter category and that category has no movement,
the time is displayed in grey. The specified timing will remain in grey until that category is provided
with a move instruction, at which point it the timing will display in white.

[Record] <Cue> [2] [Color] [Time] [7] [Enter] - records cue 2 with a cue level color time of 7.

[Record] <Cue> [2] [Time] [Time] [Time] [7] [Enter] - records cue 2 with a cue level focus

time of 7. In this example, each press of the [Time] key steps through each timing value (up
time, down time, focus time, color time and beam time.

[Record] <Cue> [2] [Time] [7] [Enter]- records cue 2 and puts a time of 7 on all parameter

categories.

N o t e :

It is not necessary to rerecord a cue to alter stored timing data. You can simply

redefine the time by specifying the cue and re-entering the time value(s).

[Cue] [5] [Time] [8] [Enter] - Redefines the all category times to 8

seconds.

[Cue] [2] {Color} [Time] [5] [Enter] - Redefines color time to 5

seconds.