Cue Playback

195

Go To Cue

[Go to Cue] instructions can be executed from any operating mode. By default, a [Go to Cue]
instruction is an out-of-sequence cue and will follow the rules of such (see

Out of Sequence Cues

above.

Following are examples of [Go To Cue]:

[Go To Cue] [5] [Enter] - all parameters with values in cue 5 are faded to those values, even

if they are tracked.

[Go To Cue] [Next] [Enter] - takes you to the next cue in the active list.

[Go To Cue] [Last] [Enter] - takes you to the previous cue in the active list.

When a [Go To Cue] instruction is executed, any null states applied with {Make Null} are removed.
To maintain the make null setting, you should use [Capture] for the required channels.

Go To Cue Timing

[Go To Cue] uses go-to-cue timing established in

Setup, page 83

. You can use a [Go To Cue]

instruction with different timing options as follows:

[Go To Cue] [2] [Time] [1] [Enter] - this command would take you to cue 2 in 1 second.

[Go to Cue] [Next] [Time] [3] [Enter] - this command would take you to the next cue in the

selected list in three seconds.

[Go to Cue] [Last] [Time] [2] [Enter] - this command would take you to the previous cue in

the selected list in two seconds.

[Go To Cue] [8] [Time] [Enter] - this command would take you to cue 8 using all timing value

stored in cue 8.

Other Go To Cue options

When [Go to Cue] is pressed, the softkeys in the CIA are changed to provide Go to Cue modifiers
to enhance your playback ability.

From these softkeys, you can specify that when going to a cue, only some elements of that cue will
be played back. Specifically you can choose to play back:

• single parameter channels only (conventionals)

[GoTo Cue] [1] {SingleParam} [Enter]

• multiple parameter channels only (moving lights)

[GoTo Cue] [2] {MultiParam} [Enter]

• move instructions only

[GoTo Cue] [3] {MovesOnly} [Enter]

• or you can choose play back a cue and withhold any link (follow, hang, execute instructions)

it may contain.

[GoTo Cue] [4] {MinusLinks} [Enter]

These can be combined within the command line as well:

[Go To Cue] [1] {MultiParam} {MovesOnly} [Enter]