Automark, Conditions triggering an automark, Allowing a live move – ETC Eos v1.3 User Manual

Page 186

Advertising
background image

172

Eos Operations Manual

AutoMark

The AutoMark feature is a system default setting and can be turned on or off at a global level. The
system default for this setting is off. To change the default settings see

Show Settings, page 85

.

When AutoMark is enabled, non-intensity parameter transitions will occur in the cue immediately
preceding
the cue in which the changes are stored, if intensity in that cue is moved from zero to any
active level. Therefore, the preceding cue “executes” the AutoMark.

AutoMark information is displayed for cues or cue parts. It is not a channel instruction. AutoMarked
cues are indicated by an “M” in the M column of the playback status display.

AutoMarks will execute using the time of the cue in which the moves occur (the cue marked by “M”).
The exception to this is if discrete timing is stored with the move instruction, in which case the
discrete time will be used.

Conditions Triggering an AutoMark

The following rules determine which channels AutoMark is applied to and how it is deployed:

• The marked cue must have a move instruction for intensity of moving lights above zero or null.

• The marked cue must have a move instruction for non-intensity parameters of those channels.

• AutoMark will not occur if the channel is receiving an intensity instruction from another source

(such as a submaster or HTP fader).

• AutoMark must be enabled for an AutoMark to occur. AutoMark is based on the current setting

of the default during playback. It does not matter what the setting is at the point of record.

• On a “per channel” basis, an AutoMark does not occur until:

Any parameter delay time has elapsed and

The intensity has reached zero and the parameter has completed any previous

movement.

Allowing a Live Move

When AutoMark is “On” it is possible to override it on a per cue (or cue part) basis. The override will
be available through a softkey, “AutoMark Off”. This softkey is not visible when AutoMark is
disabled in default settings.

AutoMark can be disabled on cues/cue parts.

When enabled, the cue that executes the mark will have an “M” in the flags field. If AutoMark is
disabled, allowing a live move, a “D” is displayed in the flags field of the cue or cue part.

The AutoMark action uses the time of the cue in which it moves (the M cue), unless it has discrete
timing. If discrete timing is stored with the move instruction, it will use that time when it moves.

By using AutoMark with multipart cues, it is possible to have some parameters mark and others
move live.

Advertising