Patching moving lights, Tutorial – ETC Eos v1.3 User Manual

Page 80

Advertising
background image

66

Eos Operations Manual

Patching Moving Lights

The process of patching moving lights requires more detail than patching a dimmer. Specific
information is required for more advanced control of the features offered by moving lights.

Tutorial

Step 1:

To patch a moving light you must first open the patch display. You may open the patch

display from the browser or by pressing [Displays]>{Patch}.

Step 2:

Enter a channel number or multiple numbers from the control keypad.

• When typing any number from the control keypad, and patch is in default

channel mode, channel is assumed and is placed on the command line. You
can use the [+], [-] and [Thru] keys to make your channel selection.

example: [1] [0] [1] [Thru] [1] [1] [0]

Step 3:

Press the {Type} touchbutton in the CIA.

Step 4:

Select a device type from the fixture library.

a: Press {Manufacturer} from the CIA to display the fixture library. The two

columns on the left are pagable and show manufacturer names.

b: Use the arrow touchbuttons to scroll the list of manufacturers. Selecting a

manufacturer repaints the device columns with all devices from that

manufacturer that are available for patching.

c: Scroll through the device list and make your selection. After the selection is

made, the fixture/device type will be placed on the command line after the

channel number and displayed in the box beneath the {Type} button.

Step 5:

Enter a starting DMX address for the selected channel or group of channels.

• Press [At] and enter the DMX address using the control keypad. The DMX

address may be entered in standard format ([1] [0] [2] [5]) or by using the port
and offset value ([3] [/] [1]).

N o t e :

Alternatively, when patch is in address mode, DMX address is assumed and is

placed on the command line. Channel mode and address mode are toggled using

the [Format] key in the patch display.

N o t e :

Notice the two softkeys {Show}, {Manfctr}, and {User} located beneath the CIA.
These softkeys provide you with the option of showing only the library of fixtures/

devices that are already patched in the show {Show} or all fixtures/devices

available in the library sorted by manufacturer {Manfctr}.
{User} displays user-defined devices. For more information, see

Fixture Creator,

page 78

.