Visualisation with »VisiWinNET®«

12.6

OPC tunnel for local visualisation (integrated control system)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

12.6

OPC tunnel for local visualisation (integrated control system)

[12-2] Local visualisation on a controller

Note!

There is no OPC server available for PROFIBUS and PROFINET.
Controller c300/p300:

• The OPC communication for »VisiWinNET« is exclusively available for Controller p300

without PLC.

• Otherwise, only the Lenze "Logic&Motion" direct driver can be used for the data

exchange between »VisiWinNET« and PLC.

• The local »VisiWinNET®« Runtime on the

controller uses the local OPC tunnel to

access the respective OPC server

(DataManager, CAN/EtherCAT, SoftPLC).

• For a local visualisation, the OPCServer.ini

configuration file must be adapted. The

configuration file is on the memory card of

the controller, directory: \USBStorage.

Configure OPC tunnel

( 119)