7programming with the »plc designer – Lenze c300 User Manual

Page 65

Advertising
background image

7

Programming with the »PLC Designer«

7.5

Creating remanent variables (retain/persistent)

65

Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.5.1

Storage of retain data on the SD card (only Controllers 3221 C/3231 C)

For Controllers 3221 C/3231 C, the values of the RETAIN variables are by default saved to the device

only.

• Use the L_Util_Retain function (from the L_Util.lib library) to save the RETAIN values to the SD

card of the controllers. Like this, the retain data can then be re-used, for instance after a device

replacement.

• RETAIN values saved to the SD card offer the benefit of subsequent use of these values after a

device replacement (subsequent use of the SD card).

L_Util_Retain

[7-1]

Program example: Use of the L_Util_Retain function

When being called, the L_Util_Retain function saves the retain/persistent variables to the SD card

to file: retains.ret (directory: IPC\PLC).

Note!

The SD card is only suitable for storing retain data if the RETAIN values do not change

very often.

• It is not possible to save the RETAIN values to the SD card during every PLC cycle.
• SD cards only have a limited number of write/read cycles. Thus, the retain variables

should not be saved at very short time intervals.

• Please avoid calling the L_Util_Retain() function in a motion task. The creation of the

RETAIN file prolongs the current PLC cycle of the calling task by several 100 ms.

• The functions SysSaveRetains() and SysRestoreRetains() provided in the

SysPlcCtrl23.Library are not supported and must not be used.

Function

Library

Function

L_Util_Retain()

L_Util.library

Save retain data to the SD card of the

controller.

PROGRAM PLC_PRG

VAR

FB_

LUtilRetain: L_Util_Retain;

xRetainsIntoFile_LUtilRetain: BOOL;
instSetRetainValues: SetRetainValues;
xSetRetain: BOOL;
xStoreRetains_LUtilRetain: BOOL;

END_VAR

Note!

Device replacement: Avoiding the loss of retain data
The L_Util_Retain function is only required for the Controllers 3221 C/3231 C.

• Use the L_Util_Retain function in the desired application in order to be able to re-use

the retain data, if required.

• In the event of a device replacement, the L_Util_Retain function must already have

been used in the application before, since otherwise the retain data are deleted.