13 parameter reference – Lenze c300 User Manual

Page 183

Advertising
background image

13

Parameter reference

13.9

Communication cards: optional interface

183

Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C1121

C1122

C1130

C1131

Parameter | Name:

C1121 | Sync master: Interface index

Data type: UNSIGNED_32

Index: 23454

d

= 5B9E

h

Note: Restart the L-force Controller after changing this parameter!
Setting range

(min. value | unit | max. value)

Lenze setting
4294967295

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C1122 | Baud rate

Data type: UNSIGNED_32

Index: 23453

d

= 5B9D

h

Baud rate of the CAN interface. The value is assigned from a selection list.
Selection list

(Lenze setting printed in bold)

7 5
6 10
5 20
3 50
8 100
2 125
1 250
0 500
4 1000

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C1130 | Tx PDO counter

Data type: UNSIGNED_32

Index: 23445

d

= 5B95

h

PDO counter for sent CAN messages
Display range

(min. value | unit | max. value)

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C1131 | Rx PDO counter

Data type: UNSIGNED_32

Index: 23444

d

= 5B94

h

PDO counter for received CAN messages
Display range

(min. value | unit | max. value)

Read access  Write access  CINH  PLC-STOP  No transfer