Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17

26

4

System structure

4.3

Runtime software of the Lenze Controllers

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.3.3

"Visu" runtime software

The "Controller-based Automation" system enables the central visualisation of the automation

system.
The visualisation can either run on a separate Controller or monitor panel or on the Controller on

which the "Logic" or "Motion" runtime software is running.
Various options described in the following sections are available for the communication link.

Functionality
The "Visu" mode ...

• extends the Controller to a visualisation device;
• can be used separately or in addition to "Logic" or "Motion".

Engineering tool required: »VisiWinNET«

Note!

There is no OPC server available for PROFIBUS and PROFINET.
Controller c300/p300:

• The OPC communication for »VisiWinNET« is exclusively available for Controller p300

without PLC.

• Otherwise, only the Lenze "Logic&Motion" direct driver can be used for the data

exchange between »VisiWinNET« and PLC.