12 visualisation with »visiwinnet – Lenze c300 User Manual

Page 118

Advertising
background image

Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17

118

12

Visualisation with »VisiWinNET®«

12.6

OPC tunnel for local visualisation (integrated control system)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Data types
The following data types are available for query:

Data type

Description

»VisiWinNET®« OPC tunnel
VT_BOOL

d11

Truth value (TRUE/FALSE)

VT_BSTR

d8

String STRING

VT_DATE

d7

Date / time format

VT_EMPTY

d0

The data type is not specified.

• This data type is e.g. returned if no process variable has been specified.

VT_I1

d16

Integer 1-byte value; signed (-128 ... 127)

VT_I2

d2

Integer 2-byte value; signed (-32768 ... 32767)

VT_I4

d3

Integer 4-byte value; signed (-2147483648 ... 2147483647)

VT_INT

d22

Integer value; signed; machine type-dependent

VT_R4

d4

Floating-point number simple accuracy (4 bytes)

VT_R8

d5

Floating-point number double accuracy (8 bytes)

VT_UI1

d17

Integer 1-byte value; unsigned (0 ... 255)

VT_UI2

d18

Integer 2-byte value; unsigned (0 ... 65535)

VT_UI4

d19

Integer 4-byte value; unsigned (0 ... 4294967295)

VT_UINT

d23

Integer value; unsigned; machine type-dependent