2 connecting the new controller/replacement device – Lenze c300 User Manual

Page 73

Advertising
background image

10

Device replacement - replacing the controller (in the event of

service)

73

Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

10.2

Connecting the new controller/replacement device

Which replacement device is suitable for the Controller?
Controllers can be replaced against each other as follows:

Principally, Panel Controllers can be exchanged against each other (despite different screen

diagonals). If the mounting dimension is to be identical, use a Panel Controller with identical screen

diagonal.
The control application of a controller is serviceable after the device replacement: Insert the suitable

controller in the »PLC Designer« and compile project.

Note!

When a replacement device is connected, all communication cards which have been

previously implemented and all terminals have to be selected identically.
The user data are stored on the memory card of the controller.
If a controller of the same product type has been used, the newly connected controller is

ready for operation after boot-up.

• The previous network settings are accepted. Alternatively they can be edited.
• After 15 seconds, the previous IP address is transferred automatically and the

controller can be accessed again.

Defective Controller

Replacement device

3221 C

3231 C

3241 C

c300

p300

p500

3221 C

-

-

-

-

3231 C

-

-

-

-

-

3241 C

-

-

-

-

-

c300

-

-

-

-

-

p300

-

-

-

-

-

p500

-

-

-

-

-

: compatible

-: incompatible