Data integrity in the event of a voltage failure

9.1

UPS functionality of the controllers

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9

Data integrity in the event of a voltage failure

9.1

UPS functionality of the controllers

9.1.1

Internal UPS (for Controllers without UPS connection)

In case of a voltage failure, retain/persistent variables, logbook data and visualisation data (e.g.

trends alarms) are saved.
The Controllers 3221 C/3231 C have an internal buffer capacitor for the short-time buffering of the

data.

The Controllers c300/p300/p500 are equipped with a high-capacity, internal UPS for the storage of

data in the event of a voltage failure. This makes external energy storage dispensable. Voltage

fluctuations cannot be compensated for.
The UPS behaviour of the internal UPS is preset. Parameter setting is not possible/required.

Controller

UPS functionality

Saves backup files to ...

3221 C

Internal capacitor for the short-time buffering of

data

MRAM (Magnetoresistive Random Access

Memory)

3231 C
3241 C

External battery pack (ACCU-PACK) or capacitor

pack (CAPS-PACK)

Memory card

c300

Internal capacitor

p300
p500