13 parameter reference – Lenze c300 User Manual

Page 166

Advertising
background image

Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17

166

13

Parameter reference

13.5

EtherCAT

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C286/7

C286/8

C286/9

C286/10

C286/11

Parameter | Name:

C286/7 | ECAT counter: Tx frames

Data type: UNSIGNED_32

Index: 24289.7

d

=

0x5EE1.0x07

h

Number of sent frames
Display range

(min. value | unit | max. value)

0

4294967295

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C286/8 | ECAT counter: Rx frames

Data type: UNSIGNED_32

Index: 24289.8

d

=

0x5EE1.0x08

h

Number of received frames
Display range

(min. value | unit | max. value)

0

4294967295

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C286/9 | ECAT counter: Lost frames

Data type: UNSIGNED_32

Index: 24289.9

d

=

0x5EE1.0x09

h

Number of lost frames
Display range

(min. value | unit | max. value)

0

4294967295

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C286/10 | ECAT counter: cyclical frames

Data type: UNSIGNED_32

Index: 24289.10

d

=

0x5EE1.0x0A

h

Number of cyclical frames
Display range

(min. value | unit | max. value)

0

4294967295

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C286/11 | ECAT counter: cyclical datagrams

Data type: UNSIGNED_32

Index: 24289.11

d

=

0x5EE1.0x0B

h

Number of cyclical datagrams
Display range

(min. value | unit | max. value)

0

4294967295

Read access  Write access  CINH  PLC-STOP  No transfer

Advertising