13 parameter reference – Lenze c300 User Manual

Page 153

Advertising
background image

13

Parameter reference

13.2

Basic parameters of the Controllers 3200 C/c300 and p300/p500

153

Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C0155

C0157

C0158

C0159

C0160

C0161

Parameter | Name:

C0155 | WinCE users: User 8 with telnet permissions

Data type: UNSIGNED_8

Index: 24420

d

= 5F64

h

User may use telnet
Setting range

(min. value | unit | max. value)

Lenze setting

0

1 0

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0157 WinCe users: User name 9

Data type: VISIBLE_STRING

Index: 24418

d

= 5F62

h

Name of the user

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0158 | WinCe users: Password 9

Data type: VISIBLE_STRING

Index: 24417

d

= 5F61

h

Password of the user

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0159 | WinCE users: User 9 with FTP permissions

Data type: UNSIGNED_8

Index: 24416

d

= 5F60

h

User may use FTP
Setting range

(min. value | unit | max. value)

Lenze setting

0

1 0

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0160 | FTP: Permissions user 9

Data type: UNSIGNED_32

Index: 24415

d

= 5F5F

h

FTP rights of the user.
Value is bit-coded:

Bit 0 Allow Read
Bit 1 Allow Write
Bit 2 Virtual Roots
Bit 3 Allow Hidden Files

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0161 | FTP: Home user 9

Data type: VISIBLE_STRING

Index: 24414

d

= 5F5E

h

Home directory of the user

Read access  Write access  CINH  PLC-STOP  No transfer