C0141

C0143

C0144

C0145

C0146

C0147

Parameter | Name:

C0141 | WinCE users: User 6 with telnet permissions

Data type: UNSIGNED_8

Index: 24434

d

= 5F72

h

User may use telnet
Setting range

(min. value | unit | max. value)

Lenze setting

0

1 0

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0143 | WinCe users: User name 7

Data type: VISIBLE_STRING

Index: 24432

d

= 5F70

h

Name of the user

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0144 | WinCe users: Password 7

Data type: VISIBLE_STRING

Index: 24431

d

= 5F6F

h

Password of the user

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0145 | WinCE users: User 7 with FTP permissions

Data type: UNSIGNED_8

Index: 24430

d

= 5F6E

h

User may use FTP
Setting range

(min. value | unit | max. value)

Lenze setting

0

1 0

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0146 | FTP: Permissions user 7

Data type: UNSIGNED_32

Index: 24429

d

= 5F6D

h

FTP rights of the user.
Value is bit-coded:

Bit 0 Allow Read
Bit 1 Allow Write
Bit 2 Virtual Roots
Bit 3 Allow Hidden Files

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C0147 | FTP: Home user 7

Data type: VISIBLE_STRING

Index: 24428

d

= 5F6C

h

Home directory of the user

Read access  Write access  CINH  PLC-STOP  No transfer